CDPNR - ARGOMIX 218, MG100462
- MSDS: CDPNR
- Manufacturer: MG INDUSTRIES
- Product Name: ARGOMIX 218, MG100462
- National Stock Number: 9130-00N050335
Product Identification
Product ID:ARGOMIX 218, MG100462
MSDS Date:12/03/1990
FSC:9130
NIIN:00N050335
MSDS Number: CDPNR
Responsible Party
VALLEY FORGE, PA 19482
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 215-695-7400
Cage: 08772
Contractor
Telephone: 610-695-7400 / 610-695-7449
Cage: 08772
Ingredients
CONSTRICTION OF VISUAL FIELDS, ENLARGEMENT OF BLIND
RTECS: 9999999ZZ
DEFICIENT DARK ADAPTATION AS WELL AS HDCH, INSOM &
RTECS: 9999999ZZ
CONCS-ADVERSE EFTS BY INTERFERING W/ITS NORM ELIM
RTECS: 9999999ZZ
VENT, REVERSING TO HYPOVENT RSLTG IN RESP ACIDOSIS;
RTECS: 9999999ZZ
W/REDNESS, TINGLING & PAIN/NUMB; HARD & WHITE SKIN &
RTECS: 9999999ZZ
HIGH
RTECS: 9999999ZZ
ING
RTECS: 9999999ZZ
MAY BE AFFECTED W/SERUM LEVELS OF CALCIUM & URINARY
RTECS: 9999999ZZ
3%-IMPAIRMENT OF PERFORMANCE. DEVEL OF TOLERANCE MAY
RTECS: 9999999ZZ
POISONING MAY
RTECS: 9999999ZZ
(APPROX 15-20 MINS). GET MED ATTN IMMED.
RTECS: 9999999ZZ
REMAINS (FOR AT LST 15 MINS). GET MED ATTN IMMED.
RTECS: 9999999ZZ
CONVLS, TACHCARDIA, ARRHYS; 50%-HYPOCALCEMIA INCL
RTECS: 9999999ZZ
ARGON
CAS: 7440-37-1
RTECS: CF2300000
Fraction By Weight: 75-92%
OSHA PEL N/K
ACGIH TLV: ASPHYXIANT
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 8-25%
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM;30000 STEL
CAR/TANK TRUCK IS INVOLVED IN FIRE. EXTING USING
RTECS: 9999999ZZ
AS FAR A DIST AS POSS. DO NOT USE WATER DIRECTLY ON
RTECS: 9999999ZZ
KEEP UPWIND. CONSIDER EVACUATION OF DOWNWIND AREA IF
RTECS: 9999999ZZ
RESTLESSNESS, PARESTHESIAS, GEN FEELING OF
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:SIMPLE ASPHY. ING
1:DEPENDS ON RAPIDITY W/WHICH OXYG DEFICIENCY DEVELS & HOW LONG IT
CONTINUES. SUDDEN ACUTE ASPHY-UNCON IMMED. SLOW DEVEL-RAPID
RESP/PULSE, AIR HUNGER, DIZZ, REDUCED AWARE NESS, TIGHTNESS IN
HEAD, TINGLING SENSATIONS, INCOORD, FAULTY JUDGEMENT, EMOTIONAL
INSTAB & RAPID FATG;(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NAUS, VOMIT, COLLAPSE, UNCON, CONVLS,
DEEP COMA & DEATH ARE POSS. ING 2:VERY VOLAT, READILY RELS GAS.
2-10%-ACIDIC TASTE, DYSP, HDCH, VERTIGO, NAUS, LABORED BRTHG, WEAK,
DROW, MENTAL CONFUSN & INCR IN BLOOD PRESS, PULSE & RESP RATE;
10%-VISUAL DISTURBS, TINNITUS, TREMORS, PROFUSE PERSPIRATION, (ING
6)
Medical Cond Aggravated by Exposure:PERSONS W/HISTORY OF CARDIOVASCULAR
OR PULMONARY TREATMENT ARE AT INCREASED RISK FROM EXPOSURE.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG HAS STOPPED, GIVE
ARTF RESP. MAINTAIN AIRWAY & BLOOD PRESS & ADMIN OXYG IF AVAIL.
KEEP AFFECTED PERS WARM & AT REST. TREAT SYMPTOMATICALLY &
SUPPORTIVELY. ADM IN OF OXYG SHOULD BE PERFORMED BY QUALIFIED PERS.
GET MD IMMED. SKIN:REMOVE CONTAM CLTHG & SHOES IMMED. WASH AFFECTED
AREA W/SOAP OR MILD DETERGENT & LG AMTS OF WATER UNTIL NO CHEM
REMAINS (ING 18)
Fire Fighting
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE. FOR LARGER FIRES,
USE WATER SPRAY, FOG OR REGULAR FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . MOVE
CNTNR FROM FIRE AREA IF YOU CAN DO IT W/OUT RISK. APPLY COOLING
WATER TO SIDES OF CNTNRS THAT ARE (SUPDAT)
Unusual Fire/Explosion Hazard:NEGLIGIBLE EXPLOSION HAZARD WHEN EXPOSED
TO HEAT OR FLAME. CYLINDER MAY EXPLODE IN HEAT OF FIRE.
Accidental Release
Spill Release Procedures:OCCUPATIONAL SPILL:STOP LEAK IF YOU CAN DO IT
W/OUT RISK. KEEP UNNECESSARY PEOPLE AWAY; ISOLATE HAZARD AREA &
DENY ENTRY. STAY UPWIND; KEEP OUT OF LOW AREAS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE ALL FED, STATE & LOC REGS WHEN
STORING THIS SUBSTANCE. FOR ASSISTANCE, CONT DISTRICT DIRECTOR OF
THE EPA. STORE I/A/W 29 CFR 1910.101.
Other Precautions:STORE AWAY FROM INCOMPAT SUBSTANCES. STORE AT TEMPS
<54F (12C). DO NOT PERMIT PHYSICAL DMG/OVERHEATING OF CNTNRS.
CONTENTS ARE UNDER PRESS; CNTNRS MAY VIOLENTLY RUPTURE & TRAVEL
CONSIDERABLE DIST. AVO ID RPTD/PRLNG CONT W/THIS SUBSTANCE.
Exposure Controls
Respiratory Protection:SPECIFIC RESP SELECTED MUST BE BASED ON CONTAM
LEVELS FOUND IN WORKPLACE & SPECIFIC OPERATION, MUST NOT EXCEED
WORKING LIMS OF RESP & MUST BE NIOSH APPROVED: ANY SUPPLIED-AIR
RESP OPERATED IN PRESS-DE MAND/OTHER POS PRESS MODE; ANY SCBA.
Ventilation:PROVIDE GENERAL DILUTION VENTILATION TO MEET PELS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . PROTECTIVE CLOTHING NOT REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:EXPOS TO FLAMES UNTIL WELL AFTER FIRE IS OUT. STAY AWAY
FROM ENDS OF TANKS. W/DRAW IMMED IN CASE OF RISING SOUND FROM
VENTING SFTY DEVICE/ANY DISCOLORATION OF TANK DUE TO FIRE. SOME OF
THESE MATLS, IF SPILLED, MAY EVAP LEAVING FLAMM RESIDUE. ISOLATE
FOR 1/2 MILE IN ALL DIRECTIONS IF TANK, RAIL (ING 3)
Chemical Properties
Spec Gravity:>1.4
Appearance and Odor:COLORLESS GAS; ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
ACRYLALDEHYDE, BARIUM PEROXIDE, HYDRAZINE, METALS, POTASSIUM. FOR
COMPLETE LIST OF MATLS TO AVOID, CONTACT NEHC .
Stability Condition to Avoid:STABLE UNDER NORMAL TEMPERATURES &
PRESSURES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
TOXIC &/OR HAZARDOUS GASES.
Disposal
Waste Disposal Methods:OBSERVE ALL FEDERAL, STATE & LOCAL REGULATIONS
WHEN DISPOSING OF THIS SUBSTANCE. FOR ASSISTANCE, CONTACT THE
DISTRICT DIRECTOR OF THE EPA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.